MIL-W-22759/87
Insulating Material: PTFE and TKT
Insulation Thickness: Size 10 to 26 - 16 mil ( 0.5 mm)
Size 6 to 8 - 22 mil ( 0.6 mm)
Size 4 - 25 mil ( 0.6 mm)
Size 2 to 04 - 25 mil ( 0.6 mm)

Wire Properties
Voltage Rating: 600
Temperature Rating: 260 C
Conductor Type: Nickel plated Copper
Construction Details: Sizes 10 to 26 have a PTFE/K/PTFE layer construction.
Sizes 6 to 8 have a PTFE layer with an intermediate K layer and a top PTFE layer.
Sizes 4 to 04 have a PTFE layer with an intermediate K layer and two top PTFE layers.
Additional Information: This specification is currently being handled by the SAE under the specification SAE-AS22759/87.
| Part ID | AWG | Strands | Conductor | Coating | Resist. | Min. Diam | Max. Diam | Min. Thick | Max Thick | Min Diam. | Max Diam | Weight | Additional Notes |
| M22759/87-26-* | 26 | 19 x 38 | Copper | Nickel | 42.2 | 0.0175 | 0.0204 | | | 0.033 | 0.037 | 1.55 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-24-* | 24 | 19 x 36 | Copper | Nickel | 25.9 | 0.0225 | 0.0244 | | | 0.038 | 0.042 | 2.15 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-22-* | 22 | 19 x 34 | Copper | Nickel | 16 | 0.0285 | 0.0314 | | | 0.043 | 0.047 | 3 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-20-* | 20 | 19 x 32 | Copper | Nickel | 9.77 | 0.0365 | 0.0394 | | | 0.051 | 0.055 | 4.55 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-18-* | 18 | 19 x 30 | Copper | Nickel | 6.1 | 0.0455 | 0.0494 | | | 0.061 | 0.065 | 6.7 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-16-* | 16 | 19 x 29 | Copper | Nickel | 4.76 | 0.0515 | 0.0554 | | | 0.068 | 0.073 | 8.6 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-14-* | 14 | 19 x 27 | Copper | Nickel | 3 | 0.0645 | 0.0694 | | | 0.081 | 0.086 | 12.95 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-12-* | 12 | 37 x 28 | Copper | Nickel | 1.98 | 0.0835 | 0.0894 | | | 0.100 | 0.105 | 20.1 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-10-* | 10 | 37 x 26 | Copper | Nickel | 1.24 | 0.106 | 0.112 | | | 0.122 | 0.127 | 31.4 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-8-* | 8 | 133 x 29 | Copper | Nickel | 0.694 | 0.158 | 0.169 | | | 0.180 | 0.188 | 57.6 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-6-* | 6 | 133 x 27 | Copper | Nickel | 0.436 | 0.198 | 0.212 | | | 0.219 | 0.229 | 88.3 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-4-* | 4 | 133 x 25 | Copper | Nickel | 0.275 | 0.25 | 0.268 | | | 0.276 | 0.288 | 143 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-2-* | 2 | 665 x 30 | Copper | Nickel | 0.177 | 0.32 | 0.34 | | | 0.344 | 0.364 | 222 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-1-* | 1 | 817 x 30 | Copper | Nickel | 0.144 | 0.366 | 0.38 | | | 0.388 | 0.408 | 289 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-01-* | 0 | 1045 x 30 | Copper | Nickel | 0.113 | 0.395 | 0.425 | | | 0.420 | 0.450 | 345 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-02-* | 00 | 1330 x 30 | Copper | Nickel | 0.089 | 0.44 | 0.476 | | | 0.475 | 0.505 | 432 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-03-* | 000 | 1665 x 30 | Copper | Nickel | 0.071 | 0.5 | 0.54 | | | 0.530 | 0.560 | 542 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M22759/87-04-* | 0000 | 2109 x 30 | Copper | Nickel | 0.056 | 0.565 | 0.605 | | | 0.590 | 0.630 | 681 | The * shall be replaced by the code code indicated in MIL-STD-681 |
The values for resistance are rated for ohms/1000ft at 20 Deg C.
The units of the diameters are in inches.
The values for weight are in lbs./1000ft.