MIL-W-5086/2
Insulating Material: Nylon or PVC
Insulation Thickness: Construction Details

Wire Properties
Voltage Rating: 600
Temperature Rating: 105 C
Conductor Type: No data available
Construction Details: For MIL-W-5086/1, /2, and /7 the insulation diameter increases with the gauge size. For example, for AWG 22 to AWG 04 with MIL-W-5086/2 the insulation thickness increases from about 0.045 mils (0.35 mm) to 0.14 mils (3.5 mm), respectively. The same trend is found with MIL-W-5086/1 and MIL-W-5086/7 for AWG 22 to AWG 10, 0.03 mils (0.8 mm)to 0.05 mils (1.3 mm), respectively.
For sizes larger than AWG 8 with MIL-W-5086/2, a nylon braid to placed on the outer layer.
Additional Information: This specification is currently being handled by the SAE under the specification SAE-AS5086/2.
| Part ID | AWG | Strands | Conductor | Coating | Resist. | Min. Diam | Max. Diam | Min. Thick | Max Thick | Min Diam. | Max Diam | Weight | Additional Notes |
| M5086/2-22-* | 22 | 19 x 34 | Copper | Tin | 16.2 | 0.029 | 0.0330 | | | 0.070 | 0.080 | 4.7 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-20-* | 20 | 19 x 32 | Copper | Tin | 9.88 | 0.037 | 0.0410 | | | 0.080 | 0.090 | 6.8 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-18-* | 18 | 19 x 30 | Copper | Tin | 6.23 | 0.046 | 0.0510 | | | 0.090 | 0.100 | 9.5 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-16-* | 16 | 19 x 29 | Copper | Tin | 4.81 | 0.052 | 0.0580 | | | 0.100 | 0.110 | 11.9 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-14-* | 14 | 19 x 27 | Copper | Tin | 3.06 | 0.065 | 0.0730 | | | 0.118 | 0.132 | 18.3 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-12-* | 12 | 37 x 28 | Copper | Tin | 2.02 | 0.084 | 0.0900 | | | 0.136 | 0.150 | 26 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-10-* | 10 | 37 x 26 | Copper | Tin | 1.26 | 0.106 | 0.1140 | | | 0.182 | 0.196 | 44 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-8-* | 8 | 133 x 29 | Copper | Tin | 0.701 | 0.158 | 0.1730 | | | 0.233 | 0.247 | 70 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-6-* | 6 | 133 x 27 | Copper | Tin | 0.445 | 0.198 | 0.2170 | | | 0.286 | 0.300 | 110 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-4-* | 4 | 133 x 25 | Copper | Tin | 0.28 | 0.25 | 0.2740 | | | 0.345 | 0.365 | 165 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-2-* | 2 | 665 x 30 | Copper | Tin | 0.183 | 0.32 | 0.3400 | | | 0.415 | 0.435 | 250 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-1-* | 1 | 817 x 30 | Copper | Tin | 0.149 | 0.36 | 0.3800 | | | 0.460 | 0.480 | 305 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-01-* | 0 | 1045 x 30 | Copper | Tin | 0.116 | 0.395 | 0.4250 | | | 0.510 | 0.540 | 400 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-02-* | 00 | 1330 x 30 | Copper | Tin | 0.091 | 0.44 | 0.4750 | | | 0.575 | 0.605 | 500 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-03-* | 000 | 1665 x 30 | Copper | Tin | 0.071 | 0.5 | 0.5400 | | | 0.635 | 0.665 | 620 | The * shall be replaced by the code code indicated in MIL-STD-681 |
| M5086/2-04-* | 0000 | 2109 x 30 | Copper | Tin | 0.056 | 0.565 | 0.6050 | | | 0.705 | 0.735 | 785 | The * shall be replaced by the code code indicated in MIL-STD-681 |
The values for resistance are rated for ohms/1000ft at 20 Deg C.
The units of the diameters are in inches.
The values for weight are in lbs./1000ft.