UL Specification Number: UL2192 / UL 2192 / UL-2192


Wire Type: Four-Conductor Style SPT-1 Cord for use in Internal Wiring of Electric Window Fans.

Standard: Appliance Wiring Material UL 758.

Issued Date: May 1, 1959

Revised Date: Dec. 8, 2000

Rating: Rating 90 C, 300 Volts.

Conductor: Four No. 18-14 AWG tinned or bare copper.

Insulation And Jacket Information: Same as for Type SPT-1 except thermoplastic (PVC) Compound suitable for use at 90 C. and Jacket

Instructions UL Representative: Detailed Examination.
Tensile Strength and Elongation of Insulation,
*Representative same as for Class 43.
* Spark Test.

UL Counter Check: (4) Detailed Examination.
Counter-Check (4) Tensile Strength and Elongation of Insulation.
Program *
* (4) Heat Shock.
* (4) Deformation.
* (4) Cold Bend.

Marking: General.

Use: For Use on Electric Window Fans where exposed to temperatures not exceeding 90 C.

The information provided above is property of UL. Full UL Copyright notice can be seen Full UL Copyright notice can be seen here..Copyright© 1995-2008 Underwriters Laboratories Inc. All rights reserved. No portion of this material may be reprinted in any form without the express written permission of Underwriters Laboratories Inc. or as otherwise provided in writing on this website.
Not what you are looking for? Submit your feedback or questions here.

Welcome to WireFacts

The goal of the WireFacts.com website is to provide a common repository for wire specification information, wire failure modes and test methods, as well as wire industry related news and materials.

This website is designed to be a community forum that allows participants to gather information and answer questions from those who handle wires. Your comments and feedback are important to us and can provide valuable information.

To find out more about providing information to be used on this website, follow this link for the details.

Recent Articles


Click here for more articles.

Ads